Pipe Section
pipe
The Ameri-Vent Oval Pipe section may be used for the following types of installation: 4" Oval - conventional Type B, Type B-2X4 when used with firestop and Type BW; 5" Oval - Type B and Type B-2X4; and 6" Oval - Type B.

Available in the following:

Sizes 4" through 5"
Lengths 6", 12", 18:, 24", 3', 4' and 5'

Size 6"
Lengths 12", 18", 24", 3'


Adjustable Length
adj. length
Adjustable Lengths telescope onto standard pipe sections to permit adjustments from 3" to 10".

Available in the following:

Sizes 4" through 6"
Length 12"
Adjust from 3" to 10"


45° Elbow - Standard
45 elbow
45° Elbow / Standard are used in pairs where offsets are desired in 1" minimum clearance enclosures or open spaces such as attics or basements. Pipe sections maybe added between pairs to produce additional offset.

Available in the following:

Sizes 4", 5", 6"


45° Elbow - Flat
45 elbow flat
45° Elbow / Flat are used where offsets are desired in 1" minimum clearance enclosures or open spaces such as attics or basements. Pipe sections maybe added between pairs to produce additional offset.

Available in the following:

Sizes 4", 5", 6"


Tee
tee
Tee branch size and Tee trunk size are the same diameter. Tee branch accepts either double or single wall pipe.

Available in the following:

Sizes 4" through 6"


Reducing Tee
reducing tee
Reducing Tee branch size is one inch smaller than Reducing Tee trunk size.

Available in the following:

Sizes 4" Tee with a 3" Branch


Tee Support
tee support
The Tee Support is used to support and center the Tee. It is to be used with the Tee Cap.

Available in the following:

Sizes 4" through 6"


Tee Cap
tee cap
The Tee Cap is used for closing off the bottom of the Tee. It is to be used with to Tee Support.

Available in the following:

Sizes 4" through 6"


Adaptors - Round to Oval
round to oval adaptor
Round to Oval Adaptors are used for conversion of vent from round to oval.

Available in the following:

Sizes 4" though 6"


Adaptor - Oval to Round
oval to round adaptor
Oval to Round Adaptors are used for conversion of vent from oval to round.

Available in the following:

Sizes 4" though 6"


Increaser
Increaser
Increasers permit increasing of vents from 4" oval to 5" oval.

Available in the following:

Sizes 4" - 5"


Tee Collar
tee collar
The Tee Collar may be used to cover the rough wall opening and the exposed double-wall branch of the Tee. The 3-4 OTVC collar features a knockout for a 3" or 4" single-wall connector.

Available in the following:

Sizes 3" through 6"


Storm Collar
storm collar
The Storm Collar serves as a counter flashing and requires mastic to seal to the vent pipe.

Available in the following:

Sizes 4" throguh 6"


All Pitch Flashing
all pitch flashing
Standard Oval Pitch Flashings install either parallel or perpendicular to the roof ridge and fit roof pitches ranging from flat to 5/12.

Available in the following:

Sizes 4" through 6"


Firestop Spacer
firestop spacer
Firestop Spacers serve as firestops at the ceiling level and centers the vent in 16" O.C. stud spaces. It is a required component for Type B- 2X4 and multi-story Type BW installations.

Available in the following:

Sizes 4" through 6"


Type BW Hold Down Plate
type bw hold down plate
Type BW Hold Down Plates are required for connecting Type BW vents to wall furnace outlets.

Available in the following:

Sizes 4"


Type BW Plate Spacers
type bw plate spacer
Type BW Plate Spacers are required at first ceiling level above a wall furnace to center and space vent properly and to provide required opening between floors. Firestop spacers must be used at subsequent levels.

Available in the following:

Sizes 4"


Type BW Attic Shield
type bw attic shield
Type BW Attic Shields are to be used on single-story or on top story of multi-story buildings for Type BW Gas Vent. Los Angeles Code and UMC requires a 26 gauge galvanized sleeve to extend from the top of the ceiling plate into the attic.

Required by Los Angeles Code and UMC

 

Other Type B Vent Components

Round Terminations
Type B Tables

 


All information is subject to change without notice. Dimensions and specifications shown are within manufacturing tolerances.
© Copyright Commercial Products Group of Hart & Cooley, Inc., October, 2007. All Rights Reserved.