Fire Stop

Parts include:

One Fire Stop

A fire stop may be required any time Saf-T Vent CI Plus penetrates combustible floors, walls, or ceilings. Remove any insulating material from the floor, wall, or ceiling cavity for at least 1" around the vent for diameters 6" - 24" and 2' around the vent for diameters 26" - 32". Review fire codes and consult with local building code officials to determine the necessity for a fire stop. The stainless steel fire stop may be trimmed provided the required clearances are maintained. HOLE DIA. VENT O.D.    
A   B C
7.4" 7.3" 20" 20"
8.4" 8.3" 20" 20"
9.4" 9.3" 26" 26"
10.4" 10.3" 26" 26"
11.4" 11.3" 26" 26"
12.4" 12.3" 26" 26"
14.4" 14.3" 26" 26"
16.4" 16.3" 26" 26"
18.4" 18.3" 26" 26"
20.4" 20.3" 32" 32"
22.4" 22.3" 32" 32"
24.4" 24.3" 32" 32"
26.4" 26.3" 32" 32"
28.4" 28.3" 36" 36"
30.4" 30.3" 36" 36"
32.4" 32.3" 40" 40"
34.4" 34.3" 40" 40"

Condensate Drain Tube Kit

Parts include:

High temperature silicone tubing
One clamp
Two cable ties

The Condensate Drain Tube Kit contains high temperature tubing rated for 500° F which is translucent to allow inspection of the P-trap. Larger diameter drains can be plumbed directly into a drain system.

Horizontal/Vertical In-Line Drain Section

Parts include:

One In-Line Drain Section
One 12" long coupler
One joint locking strap
One rotating clamps

Horizontal/Vertical In-Line Drain Section is used to drain away condensate from the vent system. The unique design of this part allows it to be installed in a horizontal, vertical, or inclined orientation. Continuous horizontal runs in excess of 30 feet require a condensate drain. The outer jacket consists of a 12" long coupler made of 430 stainless steel with an outlet for the drain. See Condensate Drain Tube Kit above. PIPE I.D. VENT O.D.    
A B C D
5" 7.3" 4.5" 0.5"
6" 8.3" 4.5" 0.5"
7" 9.3" 4.5" 0.5"
8" 10.3" 4.5" 0.5"
9" 11.3" 4.5" 0.5"
10" 12.3" 4.5" 0.5"
12" 14.3" 4.5" 0.5"
14" 16.3" 4.5" 0.5"
16" 18.3" 4.5" 0.5"
18" 20.3" 4.5" 0.5"
20" 22.3" 4.5" 0.5"
22" 24.3" 4.5" 0.5"
24" 26.3" 4.5" 0.5"
26" 28.3" 4.5" 0.5"
38" 30.3" 4.5" 0.5"
30" 32.3" 4.5" 0.5"
32" 34.3" 4.5" 0.5"

In-Line Damper Section

Parts include:

One In-Line Damper Section
One 18" long coupler
One joint locking strap
One rotating clamp
One motor platform

In-Line Damper Section is used to adjust the flow in positive pressure applications. Can also be used to restrict back flow when the appliance is off. Shaft diameter is 3/8". PIPE I.D.  
A B
5" 7.3"
6" 8.3"
7" 9.3"
8" 10.3"
9" 11.3"
10" 12.3"
12" 14.3"
14" 16.3"
16" 18.3"
18" 20.3"

In-Line Probe Section

Parts include:

One In-Line Probe Section
One 12" long coupler
One 1/4" NPT plug
One joint locking strap
One rotating clamp

 
PIPE
I.D.
A

 

B
5" 7.3"
6" 8.3"
7" 9.3"
8" 10.3"
9" 11.3"
10" 12.3"
12" 14.3"
14" 16.3"
16" 18.3"
18" 20.3"
20" 22.3"
22" 24.3"
24" 26.3"
26" 28.3"
28" 30.3"
30" 32.3"
32" 34.3"

Use the In-Line Probe Section to attach probes to the vent system by means of a 1/4" NPT female fitting. Can be used vertically or horizontally.


Increaser
Parts include:

One Drain Cover
One locking strap
One finish coupler

 
INLET
I.D.
A

OUTLET I.D.

B
6" 8"
8" 10"
10" 12"
12" 14"
14" 16"
16" 18"
18" 20"
20" 22"
22" 24"
24" 26"
26" 28"
28" 30"
30" 32"

Used to upsize a vent system. The term "Increaser" is based on an increase in vent diameter in the direction of flue gas motion. Increasers are eccentric to allow for proper drainage of condensate when installed horizontally.

Other diameter configurations may be available. Contact an AMPCO® representative.

 

Other CI Plus Components

Piping Wall Penetrations
Adjustable Lengths Terminations
Fittings Custom Fabrications
Adapters, Supports, and Guides  

 


All information is subject to change without notice. Dimensions and specifications shown are within manufacturing tolerances.