Universal Boiler Adapter

Parts include:

One Adapter
One 8" coupler band
One joint locking strap
One boiler collar clamp

Universal Boiler Adapter is used horizontally or vertically to adapt Saf-T Vent CI Plus to nominal diameter flue collars. It can also adapt to boiler collars that are slightly out of round. PIPE I.D.  
A B
5" 7.3"
6" 8.3"
7" 9.3"
8" 10.3"
9" 11.3"
10" 12.3"
12" 14.3"
14" 16.3"
16" 18.3"
18" 20.3"
20" 22.3"
22" 24.3"
24" 26.3"
26" 28.3"
28" 30.3"
30" 32.3"
32" 34.3"

Guy Support Section

Parts include:

One Guy Support Section
One 5" long coupler
One joint locking strap

Guy Support Section provides vertical support using a part that is a flue-gas-carrying component of the vent system. Guy sections are primarily installed in long, inaccessible chases or used to provide support to systems with extended lengths above the roofline. Attach the guy section using stainless steel or galvanized cables or chain (supplied by others). NOM. DIAM.  
A B
5" 4.5"
6" 4.5"
7" 4.5"
8" 4.5"
9" 4.5"
10" 4.5"
12" 4.5"
14" 4.5"
16" 4.5"
18" 4.5"
20" 4.5"
22" 4.5"
24" 4.5"
26" 4.5"
28" 4.5"
30" 4.5"
32" 4.5"

Vertical Support with 4" clearance to combustibles

Parts include:

One Vertical Support

Vertical Support with 4" clearance to combustibles supports CI Plus vent systems. See the complete installation instructions for placement. PIPE I.D. A
5" 7.3"
6" 8.3"
7" 9.3"
8" 10.3"
9" 11.3"
10" 12.3"
12" 14.3"
14" 16.3"
16" 18.3"
18" 20.3"
20" 22.3"
22" 24.3"
24" 26.3"
26" 28.3"
28" 30.3"
30" 32.3"
32" 34.3"

Vertical Support with 1" clearance to combustibles

Parts include:

One Vertical Support

Vertical Support with 1" clearance to combustibles supports CI Plus vent systems. See the complete installation instructions for placement. PIPE I.D. A
5" 7.3"
6" 8.3"
7" 9.3"
8" 10.3"
9" 11.3"
10" 12.3"
12" 14.3"
14" 16.3"
16" 18.3"
18" 20.3"
20" 22.3"
22" 24.3"
24" 26.3"

Horizontal Support for large diameter

Parts include:

One Horizontal Support

Horizontal Support for large diameter vent systems. Diameters 24" through 32" must have support every 6 feet of horizontal run. The support may be attached from the center of the bracket or from the sides of the support bracket. Support hangers by themselves do not maintain the necessary clearances to combustible materials- be certain to consider clearances when planning the system. PIPE I.D.  
A B
24" 26.3"
26" 28.3"
28" 30.3"
30" 32.3"
32" 34.3"

Support Clamp

Parts include:

One Support Clamp set (two halves)
Two 1/4-20 nuts and bolts

Horizontal Support for smaller diameter vent systems to provide support at required 6-foot intervals. Support clamps by themselves do not maintain the necessary clearances to combustible materials- be certain to consider clearances when planning the system.

This part is manufactured of 18 gauge, type 304 stainless steel and should not be installed in the direct path of flue gases.

PIPE I.D.  
A B
5" 7"
6" 8"
7" 9"
8" 10"
9" 11"
10" 12"
12" 14"
14" 16"
16" 18"
18" 20"
20" 22"
22" 24"

Roof Jack Support System

Parts include:

One Roof Jack Support
One Storm Collar

Roof Jack Support System is for use with vertical terminations. Use to pass through combustible and non-combustible roof structures. The roof jack support system must be installed on a flat roof or a level curb only (see Roof Products & Systems for acceptable roof curbs). Can not be used in a chase with a 1" clearance to vent. See Tall Cone Flashing. PIPE I.D. A B C D E
5" 7.5" 10.1" 7.25" 15" 24"
6" 8.5" 11.1" 7.25" 15" 24"
7" 9.5" 12.1" 7.25" 15" 24"
8" 10.5" 13.1" 7.25" 15" 24"
9" 11.5" 14.5" 7.25" 15" 24"
10" 12.5" 15.1" 7.25" 15" 24"
12" 14.5" 17.1" 7.25" 15" 24"
14" 16.5" 19.1" 7.25" 15" 27"
16" 18.5" 21.1" 7.25" 15" 30"
18" 20.5" 23.1" 7.25" 15" 32"
20" 22.5" 25.1" 7.25" 15" 34"
22" 24.5" 27.1" 7.25" 15" 36"
24" 26.5" 29.1" 7.25" 15" 36"
26" 28.5" 31.1" 7.25" 15" 36"
28" 30.5" 33.1" 7.25" 15" 40"
30" 32.5" 35.1" 7.25" 15" 42"
32" 34.5" 37.1" 7.25" 15" 44"

Tall Cone Flashing and Support

Parts include:

One Tall Cone Flashing
One Storm Collar
Support screws

Tall Cone Flashing and Support is used as a vertical roof penetration/support in conjunction with a combustible chase. Can be used with a roof curb if needed (see Roof Products & Systems for acceptable roof curbs). Can be used on metal roofs with a 2/12 pitch. All stainless steel construction.

A Vented Termination Collar must be used when installed in a combustible chase and must be ordered separately. Caution: support screws can only be installed with Saf-T Vent CI Plus venting.

PIPE I.D. A B C D NO. HOLES
5" 7.5" 10.75" 20" 12" 4
6" 8.5" 11.75" 20" 12" 4
7" 9.5" 12.75" 22" 12" 4
8" 10.5" 13.75" 22" 12" 4
9" 11.5" 14.75" 24" 12" 4
10" 12.5" 15.75" 24" 12" 4
12" 14.5" 17.75" 26" 12" 4
14" 16.5" 19.75" 28" 12" 6
16" 18.5" 21.75" 30" 16" 6
18" 20.5" 23.75" 32" 12" 6
20" 22.5" 25.75" 34" 12" 6
22" 24.5" 27.75" 36" 12" 6
24" 26.5" 29.75" 38" 12" 8
26" 28.5" 31.75" 40" 12" 8
28" 30.5" 33.75" 42" 12" 8
30" 32.5" 35.75" 44" 12" 8
32" 34.5" 37.75" 46" 12" 8

Pitched Tall Cone Flashing

Parts include:

One Pitched Tall Cone Flashing
One Storm Collar

Pitched Tall Cone Flashing and Support is used as a vertical roof penetration in conjunction with a combustible chase. Can be used on roofs with a 2/12 - 6/12 pitch. All stainless steel construction.

A Vented Termination Collar must be used when installed in a combustible chase and must be ordered separately.

PIPE I.D. A B
5" 8.5" 24"
6" 9.5" 24"
7" 10.5" 26"
8" 11.5" 26"
9" 12.5" 26"
10" 13.5" 28"
12" 15.5" 30"
14" 17.5" 34"
16" 19.5" 34"
18" 21.5" 36"
20" 23.5" 38"
22" 25.5" 40"
24" 27.5" 42"
26" 29.5" 44"
28" 31.5" 46"
30" 33.5" 48"
32" 35.5" 48"

 

Other CI Plus Components

Piping Wall Penetrations
Adjustable Lengths Terminations
Fittings Custom Fabrications
Accessories  

 