| Rain Cap |
|
 |
Parts include:
One Rain Cap One joint locking strap One storm
collar |
|
The Rain Cap is used as a termination on vertical
systems. Category I and II appliances require a rain
cap or other device to prevent rainwater from
entering the vent. Vent systems for positive
pressure appliances may omit the rain cap if there
are other provisions for draining rainwater from the
system. The rain cap may also be used as a
horizontal termination. Other diameter may be
available.
Contact
an AMPCO® representative. |
PIPE I.D. |
|
|
|
| A |
B |
C |
D |
| 5" |
8.5" |
14" |
14" |
| 6" |
8.5" |
14" |
14" |
| 7" |
9.5" |
18" |
18" |
| 8" |
9.5" |
18" |
18" |
| 9" |
9.5" |
20" |
20" |
| 10" |
9.5" |
20" |
20" |
| 12" |
9.5" |
24" |
24" |
| 14" |
11.5" |
28" |
28" |
| 16" |
13.5" |
32" |
32" |
| 18" |
15.5" |
36" |
36" |
| 20" |
17.5" |
36" |
36" |
| 22" |
19.5" |
44" |
44" |
| 24" |
19.5" |
48" |
48" |
| Screened Termination |
|
 |
Parts include:
One Screened Termination
One joint locking strap One finish collar |
|
Used as a termination on horizontal or vertical
systems, as specified or allowed by the appliance
manufacturer. Manufactured of AL29-4C®. |
PIPE I.D. |
|
|
|
| A |
B |
C |
D |
E |
F |
| 5" |
12.5" |
5.5" |
5" |
5" |
7.3" |
| 6" |
13.5" |
6" |
6" |
6" |
8.3" |
| 7" |
14.5" |
6.5" |
7" |
7" |
9.3" |
| 8" |
15.5" |
7" |
8" |
8" |
10.3" |
| 9" |
16.5" |
7.5" |
9" |
9" |
11.3" |
| 10" |
17.5" |
8" |
10" |
10" |
12.3" |
| 12" |
19.5" |
9" |
12" |
12" |
14.3" |
| 14" |
21.5" |
10" |
14" |
14" |
16.3" |
| 16" |
23.5" |
11" |
16" |
16" |
18.3" |
| 18" |
25.5" |
12" |
18" |
18" |
20.3" |
| Finish Collar |
|
 |
Parts include:
One Finish Collar |
|
The Finish Collar is used to close off air space
between inner vent and outer jacket. For use on
horizontal or vertical systems. Manufactured of
AL29-4C®. |
PIPE I.D. |
|
|
| A |
B |
C |
| 5" |
7.6" |
8" |
| 6" |
8.6" |
9" |
| 7" |
9.6" |
10" |
| 8" |
10.6" |
11" |
| 9" |
11.6" |
12" |
| 10" |
12.6" |
13" |
| 12" |
14.6" |
15" |
| 14" |
16.6" |
17" |
| 16" |
18.6" |
19" |
| 18" |
20.6" |
21" |
| 20" |
22.6" |
23" |
| 22" |
24.6" |
25" |
| 24" |
26.6" |
27" |
| 26" |
28.6" |
29" |
| 28" |
30.6" |
31" |
| 30" |
32.6" |
33" |
| 32" |
34.6" |
35" |
| Ventilation Collar |
|
 |
Parts include:
One Ventilation Collar |
|
The Ventilation Collar is installed over the air
space between the inner vent and outer jacket and
allows any built up heat to escape. The ventilation
collar must be used on Tall Cone Flashing
installations with a combustible chase. For use on
horizontal and vertical systems. Manufactured of 430
stainless steel. |
PIPE I.D. |
|
|
| A |
B |
C |
| 5" |
7.6" |
8" |
| 6" |
8.6" |
9" |
| 7" |
9.6" |
10" |
| 8" |
10.6" |
11" |
| 9" |
11.6" |
12" |
| 10" |
12.6" |
13" |
| 12" |
14.6" |
15" |
| 14" |
16.6" |
17" |
| 16" |
18.6" |
19" |
| 18" |
20.6" |
21" |
| 20" |
22.6" |
23" |
| 22" |
24.6" |
25" |
| 24" |
26.6" |
27" |
| 26" |
28.6" |
29" |
| 28" |
30.6" |
31" |
| 30" |
32.6" |
33" |
| 32" |
34.6" |
35" |
|
|

All information is subject to change without notice. Dimensions and specifications shown are within
manufacturing tolerances.
© Copyright Commercial Products Group of Hart & Cooley, Inc., October, 2007. All Rights Reserved.